CG Rubber Stopper(Bung) Processor Medical Instrument Sterilizer For Pharmaceutical Industry

According to the specific cleaning and sterilization process, pre-cleaning, heating sterilization, vacuum displacement drying and cooling of the injection plug were carried out to make it meet the required quality requirements for production and application. After the cleaning and sterilization process is adopted, the injection plug can meet the corresponding quality requirements. The scientific and reasonable cleaning and sterilization process can make the indicators of the injection plug meet the production and application standards and effectively guarantee the quality of the injection.

  • Product Description
  • Technical Parameters
  • Video

Rubber Stopper(Bung) Processor Medical Instrument Sterilizer Description:

Plugs are generally made of rubber, which is easy to produce a large number of collodion chips and pollutants. Although they are simply rinsed with water after production by the manufacturer. For the bung processor, rubber crumb is very stubborn, and is not easy to wash off, the other is in the packing and shipping process to produce secondary pollution, so give each big pharmaceutical factory of rubber plug, according to the national GMP, pharmaceutical factory cannot be used directly, so companies must be cleaned before use disinfection, cleaning and disinfection of the scientific technology should be adopted, avoid contamination of rubber plug For injection, Affect the effect of the injection.

medical instrument sterilizer,bung processor,steam sterilizer,clean sterilizer,pharmaceutical sterilizer manufacturer

Steam is a good sterilization medium, with pure steam sterilization ability, and fewer impurities, mainly used in pharmaceutical equipment and system sterilization. The working principle of a steam sterilizer is to use the pure steam with strong permeability to create wet and hot conditions, which deform and solidify the protein and protoplasm colloid in the organism and destroy the enzyme system. In addition, the steam enters the cell to condense into water, releasing potential heat, raising the temperature, and further enhancing the bactericidal effect.

medical instrument sterilizer,bung processor,steam sterilizer,clean sterilizer,pharmaceutical sterilizer manufacturer

 Medical Instrument Sterilizer Features:

1. Medical instrument sterilizer is mainly used for cleaning and disinfection of rubber plug (aluminum cover) in pharmaceutical factory.

2. It can automatically complete the cleaning, sterilization, drying, cooling and other procedures of the medical rubber plug (aluminum cover).

3. The clean sterilizer has integrated cleaning, sterilization, drying in one, automatic heating, automatic entering forced humidification, constant temperature and sterilization process. The door will not open during the working of the equipment, and the structure of the equipment is complicated and simple.

4. PLC programmable, man-machine interface touch screen display, sensitive equipment control, accurate display, strong anti-interference, control without deviation. 5. The thermal insulation performance of the whole machine is good, the door is well sealed, and the water temperature must not overflow.

5. Easy to operate, correct action, low failure rate, all devices in the box can be disassembled, easy to check (maintenance) repair and equipment cleaning.

medical instrument sterilizer,bung processor,steam sterilizer,clean sterilizer,pharmaceutical sterilizer manufacturer

6. Optional remote monitoring system

medical instrument sterilizer,bung processor,steam sterilizer,clean sterilizer,pharmaceutical sterilizer manufacturer

 

 

Leave a Reply

Your email address will not be published. Required fields are marked *

Technical parameters
Design pressure Working Pressure Design Temperature Working Temperature Heat Equilibrium
0.245Mpa 0.22Mpa 139℃ 134℃ ≤±1℃
Vacuum Steam Source Pressure Water Source Pressure Compressed Air Pressure WFI/Pure Steam Pressure
-0.095Mpa 0.4-0.6Mpa 0.2-0.3Mpa 0.6-0.8Mpa 0.2-0.3Mpa
Model Overall Dimensions  L*M*H(mm)
Single/Double Door
Chamber Size L*W*H(mm) Sream Consumption (kg/cycle) Power (KW) Water consumption Net Weight (kg)
CG-0.1 825*1080*1600 630*400*480 15 1.0 80 380
CG-0.25 895*1220*1720 700*600*600 20 1.5 150 650
CG-0.36 1195*1220*1720 1000*600*600 25 1.5 180 760
CG-0.6 1245*1300*1880 1050*680*850 30 2.0 200 1100
CG-0.8 1595*1300*1880 1400*680*850 35 3.0 250 1300
CG-1.2 1695*1370*1960 1500*750*1100 40 3.0 300 1900
CG-2.5 3195*1370*1960 3000*750*1100 75 4.5 500 2800
CG-5.0 3635*1800*2200 3400*1000*1500 150 7.5 700 4500