• ethylene oxide sterilization of syringes,disposable syringe sterilization,glass syringe sterilization 

EO Plus Ethylene Oxide Sterilization Of Syringes Disposable Plastic/Glass Syringe Sterilization

ETO sterilization is suitable for single-use surgical supplies, pharmaceutical and pharmaceutical industries, laboratories and hospitals. EO sterilization equipment for medical supplies: non-woven medical supplies, syringes, infusion sets, surgical gloves, various rubber infusion catheters, sutures, anesthetics, sanitary napkins, medical dressings.

  • Product Description
  • Technical Parameters
  • Video

Ethylene Oxide Sterilization Of Syringes Disposable Plastic/Glass Syringe Sterilization Description:

Now, disposable syringe manufacturers use ethylene oxide sterilization syringes, and eo sterilization is used more widely.

ethylene oxide sterilization of syringes has some advantages. Ethylene oxide sterilization kills all microorganisms, including bacterial spores. If the syringe has been sterilized, you can wrap the sterile syringe to keep the syringe sterile. Ethylene oxide does not etch plastic, metal and rubber materials. Ethylene oxide can penetrate irregular products.

ethylene oxide sterilization of syringes,disposable syringe sterilization,glass syringe sterilization 

Ethylene Oxide Sterilization Of Syringes Features:

1. The operation process is controlled by PLC+ industrial computer.

2. Sterilization time is generally 8 ~ 12h.

3. The device has the following alarm functions: (a) sensor fault alarm (b) dose alarm (c) overpressure alarm (d) high temperature alarm (e) opening and closing alarm: audible alarm when opening and closing.

4. Single machine can complete the whole sterilization process independently, and the sterilization effect is reliable

5. Applicable to hospital operating rooms, scientific research units, chemical laboratories, archives

How to use eto sterilization?

Prerequisite: Expose the product to a warm, humid environment for at least 12 hours (70%RH, 55 ° C) to ensure that the product is at a uniform temperature and humidity.

Exposure: Vacuum and introduction of EtO gas. The product is usually exposed for 4-8 hours. During this process, the relative humidity is maintained at approximately. 70% and the temperature is 55°C.

Post conditions: EtO gas is removed by repeatedly vacuuming and then introducing air into the sterilization chamber until EtO gas is removed (8-12 hours).

Leave a Reply

Your email address will not be published. Required fields are marked *

Model Outer Size(L×W×H)
Volume of inner container: 1,3, 6, 10, 15, 20……..100m3
Chamber material Inner chamber and outchamber,and all pipes directly connect with EO gas and steam are stainless steel
Sterilizing temperature 20-100℃
Sterilizing pressure -90~+80Kpa
EO concentration 250~200mg/L
Pre-Vacuum -90Kpa(vacuum can be done sectionalized)
Sterilizing time 3~24 hours choosable
Heating Maximum Power 54KVA
Power source 3-phase,5-wire 380V 50Hz

Video