• eto sterilization machine,gas sterilizer,eto sterilizer

EO Plus ETO Sterilization Machine Of Plastic/Metal/Fabric Product Gas Sterilizer

With our highly advanced infrastructure and extensive knowledge, we are committed to offering a commendable range of ETO (ethylene oxide) gas sterilizers. Ethylene oxide (ETO) sterilizers are primarily used to sterilize medical, surgical and pharmaceutical products that cannot support traditional high-temperature steam sterilization – such as corporate electronic components, equipment in plastic packaging or plastic containers, fabrics, etc.

  • Product Description
  • Technical Parameters
  • Video

ETO Sterilization Machine Of Plastic/Metal/Fabric Product Gas Sterilizer Features:

Advantages:

1. A wide range of application, ethylene oxide can be used for high temperature, not resistant to humidity items sterilization.

2. Low cost, compared with other sterilization methods, ethylene oxide sterilization cost is lower.

3. Strong penetration, can be used for a variety of difficult to penetrate the sterilization of parts: such as some thinner, longer catheterization with other low temperature sterilization methods is difficult to achieve sterilization effect, and can only be sterilized with ethylene oxide.

eto sterilization machine,gas sterilizer,eto sterilizer

Ethylene oxide sterilization process introduction

The ethylene oxide sterilization process includes pretreatment (heating, humidification, pre-vacuum) – dosing – sterilization – cleaning – analysis (residue removal).

The heating and humidification can be carried out in the ethylene oxide sterilizer, or the preheating room can be configured separately, and the heating and humidification can be carried out in the preheating room, and then transferred to the sterilizer when the temperature and humidity of the product meet the requirements.

The analysis (residue removal) can be carried out in the ethylene oxide sterilization cabinet, or can be transferred to a special analysis room, so that the ethylene oxide residue in the sterilized items is released to meet the product residue standard, such as the residue requirement of masks after ethylene oxide sterilization ≤10μg/g.

Leave a Reply

Your email address will not be published. Required fields are marked *

Model Outer Size(L×W×H)
Volume of inner container: 1,3, 6, 10, 15, 20……..100m3
Chamber material Inner chamber and outchamber,and all pipes directly connect with EO gas and steam are stainless steel
Sterilizing temperature 20-100℃
Sterilizing pressure -90~+80Kpa
EO concentration 250~200mg/L
Pre-Vacuum -90Kpa(vacuum can be done sectionalized)
Sterilizing time 3~24 hours choosable
Heating Maximum Power 54KVA
Power source 3-phase,5-wire 380V 50Hz

Video