Hospital Prefilled Glass Syringe Sterilization Ventilate Steam Sterilizer Machine Description:

Glass is a non-coma transparent solid obtained by high temperature melting and cooling, and is one of the most stable materials in chemistry. This kind of product not only has good water resistance, acid resistance and general alkali resistance, but also has good thermal stability, certain mechanical strength, smooth, transparent, easy to clean and disinfect, high barrier, easy to seal and so on. It can be widely used in packaging of various pharmaceutical preparations.

The glass syringe has smooth surface, small friction between plug and needle, free tooth, convenient operation and low price. Glass syringes are more excellent in puncture, automatic needle return and time consuming. However, glass syringes are easily damaged and rarely used in clinic.
The glass syringe is sterilized before use and is “autoclelled” with high temperature steam to flow the syringe with no residual impurities and ensures the quality and safety of the product. Steam Sterilizer machine is one of the essential equipment in hospital steam sterilizers. It has the characteristics of fast cleaning, safety and infection prevention. The sterilization of a substance resistant to heat and humidity is achieved by denaturation of the protein using high temperature saturated water vapor and the death of the microorganism within a certain period of time.

The cooling coil provides the drying and cooling of the equipment and the product is terminal of prefilled syringes, the introduced cooling water cooling coil condenses the mixed gas sterilization chamber, and the water spots on the product surface are evaporated, the last time limiting the cooling and drying.


Hospital Prefilled Glass Syringe Sterilization Ventilate Steam Sterilizer Machine Features:
1.Seiko production box and interior
The main body uses a giant box structure, and the box has a reinforcing structure of a reinforcing structure, and the liner is made of an inlet acid stainless steel 304 welding, outer wall and the carbon steel sheet for reinforcing the gluten. The sterilization indoor surface is perfectly mechanically refined and polished.

2. Door lock device
The cylinder driver locking device is used, and the operation is flexible and easy to repair. Reliable mechanical electrical interlocks ensure safe operation.
3. Sealing strip
The door seal is made of silicone rubber, which is more than 200 ° C, and the unique dovetail embedded design ensures the sealing of the door.

4. Reliable and stable microcomputer automation control
Data record, print, and save functions. The main control system uses touch screen PLC control, both use the world to ensure reliable operation. In terms of data management, instant printing is available, or CF card disk printing can be selected.
5. Exquisite decorative hood
The sterilization cabinet hood is made of brushed stainless steel plates, beautiful and durable and easy to clean hygiene treatment.

6. Sterile guarantee and equipment
The device is combined by the conventional temperature time control with the accumulation of the F0 value, and the double prosecution guarantees the sterilization effect, and the multi-point measurement control temperature is more effectively eliminating the effect of the sensor.
The equipment is accompanied by a standard GMP authentication interface, which can provide users with GMP authentication.

7. Pressure tracking control
For the sterilization of the plastic container, the temperature and pressure parameters used in the sterilization phase depends on the liquid and container material that requires sterilization, and any change in the pressure must be connected to the temperature correctly.
Due to accurately use PID temperature control technology, accurately real-time pressure tracking, quickly cooling technology is reasonably used, so that the plastic container avoids the packet, deformed, discolored, etc., which can be achieved in the entire sterilization engineering.

8. Fast and uniform cooling, drying system
The cooling and drying of the sterilized product is to introduce external cooling water into the coating tube group, and the steam in the sterilization chamber will cool down, and then through the high energy double-speed blower, the airflow is mandatory in the middle of the cabinet. The moisture of the product surface evaporates to achieve cooling and drying effect.
9. Optional remote monitoring system
The sterilizer has wireless communication function, which can be connected to the remote monitoring end through terminal routing, and the data can be directly monitored in real time via WiFi or 4G/5G network to realize remote monitoring of sterilization status, temperature, sandwich pressure, F0 value, front and back door status and other information. With high precision and high acquisition rate, the sterilization environment can be monitored 24/7, improving the operational efficiency of sterilization.
If the temperature, pressure and time data are abnormal and do not meet the pressure steam sterilization requirements, the operator can see the abnormal information on the platform.