In order to ensure the accuracy of the experimental results and the smooth progress of the experiment, the glassware used in the experiment is required to be cleaned very clean. Strict and correct operation mode is the key, and the appropriate sterilization equipment directly affects the experimental results, or even leads to the failure of the experiment. High temperature sterilization steam generator brought by the wet heat sterilization method, gas production fast steam pure, sterilization effect is obvious.

  • Product Description
  • Technical Parameters
  • Video

High Pressure Autoclave Laboratory Glassware Autoclave Sterilizer Description:

The advantage of Glassware Autoclave’s dampness and heat sterilization method is that steam has a strong bactericidal effect. It can increase the water content of bacteria proteins and make them easy to solidify due to heat, accelerating the death process of microorganisms. In terms of safety control, autoclave steam sterilizer has several sets of safety interlocking devices, including overpressure self-discharging, water breaking protection and automatic overtemperature control.

glassware autoclave,autoclave steam sterilizer,laboratory sterilizers,sterilization of laboratory glassware,high pressure autoclaveThe operating system of laboratory Sterilizers adopts PLC Siemens control system. The LCD window on the control table shows the whole sterilization dynamic and functional operation. The main components of glassware are made of stainless steel, sterilization index is up to medical surgical level standard, and all kinds of microorganisms and their spores or spores on the sterilized glassware can be killed within half an hour when the steam pressure and steam temperature rise to a certain value. High Pressure Autoclave is an ideal product for sterilization or disinfection of pressure and high temperature steam resistant operating room and laboratory instruments.

glassware autoclave,autoclave steam sterilizer,laboratory sterilizers,sterilization of laboratory glassware,high pressure autoclave

High Pressure Autoclave Laboratory Glassware Autoclave Sterilizer Features:

1. The sterilization cabinet is developed and designed according to the actual situation of the animal laboratory and the requirements of relevant regulations.

glassware autoclave,autoclave steam sterilizer,laboratory sterilizers,sterilization of laboratory glassware,high pressure autoclave

2. 316L stainless steel is used in the inner liner of the product to avoid the corrosion of sterilized items on the chamber, and the service life of the equipment can reach more than 10 years.

3. The discharge system adopts multi-stage filtering and blocking device, which is convenient for users to clean and maintain the discharge pipeline.

4. The equipment can be equipped with spray cleaning device, convenient for users to maintain the sterilization cabinet.

glassware autoclave,autoclave steam sterilizer,laboratory sterilizers,sterilization of laboratory glassware,high pressure autoclave

glassware autoclave,autoclave steam sterilizer,laboratory sterilizers,sterilization of laboratory glassware,high pressure autoclave

5. Super vacuum system, aiming at the characteristics of large workload of experimental animals and poor penetration of sterilized items, the vacuum system design is 1.2-1.5 times higher than the conventional sterilizing cabinet vacuum rate.

6. High safety and reliability, with cabinet door safety interlocking interlocking device, improve the safety of operators and equipment environment.

7. Personalized sterilization program design: equipment for different sterilization items, preset multiple sterilization programs for users to choose, such as: feed, cage, drinking water, etc.;

glassware autoclave,autoclave steam sterilizer,laboratory sterilizers,sterilization of laboratory glassware,high pressure autoclave

 

 

 

Leave a Reply

Your email address will not be published. Required fields are marked *

Technical indicators
Design pressure Working Pressure Design Temperature Working Temperature Heat Equilibrium Vacuum Steam Source Pressure Water Source Pressure Compressed Air Pressure
0.245Mpa 0.22Mpa 139℃ 134℃ ≤±1℃ -0.095Mpa 0.4-0.6Mpa 0.2-0.3Mpa 0.6-0.8Mpa
Specifications Overall Dimensions Chamber Size Steam Consumption Power Water Consmption Net Weight
Model L*M*H(mm) L*W*H(mm) (kg/cycle) (KW) (kg/cycle) (kg)
Single/Double Door
YG-0.1 825*1080*1600 630*400*480 15 1 80 380
YG-0.25 895*1220*1720 760*600*600 20 1.5 150 650
YG-0.36 1195*1220*1720 1000*600*600 25 1.5 150 760
YG-0.6 1245*1300*1880 1050*680*850 30 2 200 1100
YG-0.8 1595*1300*1880 1400*680*850 35 3 250 1300
YG-1.2 1695*1370*1960 1500*750*1100 40 3 300 1900
YG-2.5 3195*1370*1960 3000*750*1100 75 4.5 450 2800
YG-5.0 3635*1800*2200 3400*1000*1500 150 7.5 600 4500

Video

YG 5.0 Steam Autoclave:

Medical Waste Disposal:

Circular Chamber Construction:

Rectangular Chamber Construction: