• oscillating motion,water spray autoclave,retort autoclave

ZDG Series Oscillating Motion Water Spray Autoclave Food/Drug Retort Autoclave

Mainly used in food and drug industry. This device can quickly eliminate bacteria on the surface of objects, without excessive cooking, without loss of product texture. You’ll get a colored, high-quality product that won’t fall apart and has unbeatable flavor thanks to reduced cycle time. Compared with static or rotary sterilizer, there are significant differences.

  • Product Description
  • Technical Parameters
  • Video

Oscillating Motion Water Spray Autoclave Food/Drug Retort Autoclave Description:

oscillating motion,water spray autoclave,retort autoclave

The utility model provides an oscillating sterilizer, which can make the product move back and forth, thus accelerating the heat transfer in the package, reducing the heating and diathermy time, and improving the taste of food. Oscillating sterilizer can not only provide uniform heating effect, but also horizontal reciprocating stirring, so that food evenly mixed.

The oscillating motion water spray autoclave can complete the sterilization of articles under the condition of high temperature vibration, with good sterilization effect, maximum retention of components, simple structure and other advantages.

oscillating motion,water spray autoclave,retort autoclave

Oscillating Motion Water Spray Autoclave Features:

1. Adopt unique internal structure design, with small heat loss, high energy utilization rate, high sterilization efficiency.

2. The intelligent control system is composed of PLC control system, sensor and actuator. The control system can monitor all kinds of parameters and the running state of the equipment in real time, control the equipment, and make it run in a coordinated and stable way.

oscillating motion,water spray autoclave,retort autoclave

3. According to different sterilization procedures of customers, control parameters can be modified to realize sterilization process management.

4. With graphic configuration, trend curve, alarm record, data processing, report output and other functions, it plays an important role in the process analysis of sterilization.

5. Adjustable vibration frequency, material evenly tumbling, more thorough sterilization.

oscillating motion,water spray autoclave,retort autoclave

Leave a Reply

Your email address will not be published. Required fields are marked *

Design pressure 0.245Mpa Steam Pressure 0.4-0.6Mpa
Working Pressure 0.22Mpa Water  Pressure 0.1-0.3Mpa
Design Temperature 139℃ Compressed Air Pressure 0.5-0.7Mpa
Working Temperature 60-134℃ Rotation Speed 1-20rpm
Heat Equilibrium ≤±0.5℃
Model Overall Dimensions L*W*H(mm) Chamber Size L*W*H(mm) Steam Consumption(kg/cycle) Soft Water(kg/cycle) Cart (pcs) Power(KW) Net Weight(kg)
ZDG-0.3 1195x1220x1720 1000x600x600 25 150 1 2.5 850
ZDG-0.6 1245x1300x1880 1050x680x850 30 200 1 2.5 1400
ZDG-1.2 1695x1370x1960 1500x750x1100 40 300 2 1.5 1850
ZDG-1.5 2015x1370x1960 1820x750x1100 80 350 2 2 2100
ZDG-2.0 2695x1370x1960 2500x750x1100 130 420 3 3 2500
ZDG-2.5 3195x1370x1960 3000x750x1100 180 470 3 3 3000
ZDG-5.0 3635x1800x2200 3400x1000x1500 350 650 4 4.5 4200