• pulse vacuum sterilizer, steam sterilizer autoclave, medical autoclave
  • pulse vacuum sterilizer, steam sterilizer autoclave, medical autoclave
  • pulse vacuum sterilizer, steam sterilizer autoclave, medical autoclave
  • pulse vacuum sterilizer, steam sterilizer autoclave, medical autoclave

YG Series Pulse Vacuum Sterilizer Medical Steam Sterilizer Autoclave

In health care, disinfection of medical supplies is a key issue in combating the spread of many infectious diseases. In order to improve the quality of this supply, international standards have been developed which set out the requirements for equipment and procedures in the sterilization departments of medical institutions. The hospital autoclave provides optimal solutions for central aseptic supply departments (CSSD) in hospitals, clinics, and the pharmaceutical and biotechnology industries.

  • Product Description
  • Technical Parameters
  • Video

Pulse Vacuum Sterilizer Medical Steam Sterilizer Autoclave Description:

One of the most important components of the hospital run is to provide the steam required for high pressure sterilizer. Hospital laboratories and operating rooms regularly use high-pressure sterilizers to disinfect the various instruments needed for medical procedures. Without it, the hospital cannot guarantee that their medical equipment and instruments have no bacteria and bacteria, which is essential for any hospital.

hospital steam sterilizers,pre vacuum steam sterilizer,pulse vacuum steam sterilizer,steam sterilizer machine,steam sterilizers for hospitals

Pulse vacuum sterilizers make use of the vacuum system of the equipment to force out the air in the sterilization room and then enter the saturated pure steam at a certain time and temperature (pressure). When saturated pure steam is in contact with the sterilized substance, the protein of bacteria and microorganisms is denaturated and killed using the principle of heat dissipation, so as to achieve the effect of sterilization and disinfection. When the steam sterilizers for process is over, the steam in the sterilization chamber is discharged, and the vacuum system is started to vacuum the inner chamber, and the steam in the inner chamber and the water in the sterilized products are extracted, so as to achieve the effect of sterilization.

 

Application:

Used to sterilize (make sterile) objects such as medical equipment, glassware, surgical equipment and other materials through the use of high-pressure steam. For example, surgical instrument kits, glass containers, test tubes, syringes, plastic catheters, masks, protective clothing, plastic infusion bags and other medical equipment.

Solid, liquid, hollow and instruments of various shapes and sizes can be sterilized by autoclave.

pulse vacuum sterilizer, steam sterilizer autoclave, medical autoclave

Pulse Vacuum Sterilizer Features:

1. With double jacket construction, complete recessed jacket should be provided around the chamber to avoid steam condensation and promotion, and appropriate temperature distribution. It can be heated evenly to prevent the material from uneven heating.

2. Chamber: the chamber is made of SUS316L, according to mechanical and chemical treatment, the surface of the chamber is bright, the Angle of the chamber is arc transition, no cleaning dead Angle, corrosion resistance. Two stainless steel guide rails shall be provided in the chamber as the rails for the loading car.

3. The insulation layer is made of aluminosilicate, the best insulation material, and the equipment is rectangular with stainless steel decorative cover.

4. The door:
– Autoclave design is straight-through (double door) autoclave. Front and rear doors won’t open at the same time.
– The door seal is inflatable, pressurized with compressed air and can withstand chamber temperature and pressure.
– The door shall have a safety mechanism to prevent the door from opening when the chamber is hot or pressurized or when pressurized in an autoclave.
– Sterilization cycle can only be started after the door is completely closed and locked.

5. Pipeline system consists of filter, vacuum pump, pneumatic valve and so on.
– Air filters are Pall brand. Excellent performance, no medium fracture or pollution unloading.
– Vacuum pump: Autoclave includes liquid ring vacuum pump to obtain vacuum in the chamber, ensuring proper air removal for excellent sterilization.
– Angle pneumatic valve: strong on/off valve, without any error, remote compressed gas control. Stainless steel clamp seat for inner cabin.

 pulse vacuum sterilizer, steam sterilizer autoclave, medical autoclave

6. Control system:
-PLC + HMI control +Micro- data printing, should be able to default one or more sterilization cycles. Electrical equipment system adopts domestic or imported parts, its performance is stable and reliable.
– Advanced control function, large storage capacity, trouble-free operation time up to 50,000 hours.
– Primary controller system: You can set the user name and password, and set different users to access the system. It has three interface functions: manager, user and maintainer. The administrator can set the password according to different levels of use, to ensure the use of security, to prevent improper operations or modify the program to bring about experiments.
– When the automatic controller is in failure, the safety device keeps the sterilization chamber pressure safe under the atmosphere pressure to the back of the state and allows the loading door to be opened.
– Manual operations can be done using access control tools for maintenance, testing and emergency needs.

 

7. Touch screen:
– Display working process parameters, simple control, easy to operate.

 pulse vacuum sterilizer, steam sterilizer autoclave, medical autoclave

8. The interface has the following functions:
– Display screen shows sterilization cycle status, time, pressure, temperature, double door density, operation record, printing and other processes.
Printer: real-time output can be realized by micro needle printer, which can easily output “pressure, temperature, time, F0 value” and other parameters and curves.
– The autoclave has an emergency stop mechanism designed to immediately stop all physical movement of the device.
– Fixed GMP validation connector can provide GMP validation for customers free of charge.

 

9. Optional remote monitoring system

The sterilizer has wireless communication function, which can be connected to the remote monitoring end through terminal routing, and the data can be directly monitored in real time via WiFi or 4G/5G network to realize remote monitoring of sterilization status, temperature, sandwich pressure, F0 value, front and back door status and other information. With high precision and high acquisition rate, the sterilization environment can be monitored 24/7, improving the operational efficiency of sterilization.
If the temperature, pressure and time data are abnormal and do not meet the pressure steam sterilization requirements, the operator can see the abnormal information on the platform.

 

 

Related products:

 

Medical Autoclave With Shredder

Biomedical Waste Shredder

Ventilation sterilizer

Water Bath Sterilization

 

Leave a Reply

Your email address will not be published. Required fields are marked *

Design pressure Working Pressure Design Temperature Working Temperature Heat Equilibrium Vacuum Steam Source Pressure Water Source Pressure Compressed Air Pressure
0.245Mpa 0.22Mpa 139℃ 134℃ ≤±1℃ -0.095Mpa 0.4-0.6Mpa 0.2-0.3Mpa 0.6-0.8Mpa
Specifications Overall Dimensions Chamber Size Steam Consumption Power Water Consmption Net Weight
Model L*M*H(mm) L*W*H(mm) (kg/cycle) (KW) (kg/cycle) (kg)
Single/Double Door
YG-0.1 825*1080*1600 630*400*480 15 1 80 380
YG-0.25 895*1220*1720 760*600*600 20 1.5 150 650
YG-0.36 1195*1220*1720 1000*600*600 25 1.5 150 760
YG-0.6 1245*1300*1880 1050*680*850 30 2 200 1100
YG-0.8 1595*1300*1880 1400*680*850 35 3 250 1300
YG-1.2 1695*1370*1960 1500*750*1100 40 3 300 1900
YG-2.5 3195*1370*1960 3000*750*1100 75 4.5 450 2800
YG-5.0 3635*1800*2200 3400*1000*1500 150 7.5 600 4500

Video