• pure water treatment machine,reverse osmosis water treatment,water treatment system machine,commercial reverse osmosis water system,double pass reverse osmosis system
  • pure water treatment machine,reverse osmosis water treatment,water treatment system machine,commercial reverse osmosis water system,double pass reverse osmosis system
  • pure water treatment machine,reverse osmosis water treatment,water treatment system machine,commercial reverse osmosis water system,double pass reverse osmosis system

Water-RO Commercial Single/Double Pass Reverse Osmosis Pure Water Treatment Machine System

Reverse osmosis is a membrane separation technology developed in the eighties, it mainly uses the osmosis principle of semi-permeable membrane, through a certain way to impose a pressure on it, against the force of natural osmosis direction, so that the water in the thick solution to dilute solution, this way is called reverse osmosis. A device consisting of reverse osmosis elements is a reverse osmosis device.

  • Product Description
  • Technical Parameters
  • Video

Single/Double Pass Reverse Osmosis Pure Water Treatment Machine System Description:

The reverse osmosis membrane used by pure Water Treatment machine is a semi-permeable spiral coil membrane. When raw water is sent to the reverse osmosis membrane at a certain pressure, water penetrates through the tiny aperture of the membrane and is collected to obtain pure water, while impurities in the water, such as soluble solids, organic matter, colloidal substances and bacteria, are intercepted by the reverse osmosis membrane. It is concentrated in the interceptor and removed.

Single stage reverse osmosis can remove more than 97% of the dissolved solids in raw water, double stage reverse osmosis can remove more than 99% of the dissolved solids, more than 99% of the organic matter and colloid, almost 100% of the bacteria. Double pass reverse osmosis system is the use of a pure water into two as raw water use, can make the pure water to achieve higher quality, suitable for high pure water production needs, can also be used for raw water conductivity is higher occasions.

Reverse osmosis water treatment is one of the advanced equipment to make pure water in the water treatment equipment in the world at present, its operation cost is low, economic, convenient operation, reliable operation, is the business of making pure water equipment. The production capacity of the water Treatment System machine is the value under the standard production condition of raw water at 25℃. Changes in water temperature and production conditions will affect the production capacity of the equipment.

Commercial reverse Osmosis water system is one of the pure water processing equipment in the world at present, its operation cost is low, economic, easy to operate, reliable operation, is the user’s first choice of pure water equipment.

pure water treatment machine,reverse osmosis water treatment,water treatment system machine,commercial reverse osmosis water system,double pass reverse osmosis system

Single/Double Pass Reverse Osmosis Pure Water Treatment Machine System Features:

Single stage reverse osmosis process features:

1. Suitable for areas with high salt content of raw water

2. Good conductivity of water production

3. Low one-time investment

4. Low operating cost

5. Good stability

Two-stage reverse osmosis process features:

1. Suitable for areas with low salt content in raw water

2. Low total carbon (organic matter) from water

3. Relatively simple structure

4. Pollution-free emissions

Main properties of reverse osmosis membrane:

● Comprehensive desalination rate >97~99%

● The effective removal of organic compounds interception molecular weight >150MW

● Bacteria removal rate >99%

● Pyrogen removal rate >99%

● Removal rate of silica >98.5%

● Removal rate of heavy metal ions >96~99%

Leave a Reply

Your email address will not be published. Required fields are marked *

 Single stage reverse osmosis
Model Water output(m3/h) Minimum water intake(m3/h) Desalination rate(%) Temperature of the working water(℃)
Water-Ro0.3 0.3 1.2 98 5-35
Water-Ro0.5 0.5 2 98 5-35
Water-Ro1 1 2.5 98 5-35
Water-Ro2 2 3.6 97 5-35
Water-Ro3 3 5 97 5-35
Water-Ro4 4 5.3 97 5-35
Water-Ro6 6 11 97 5-35
Water-Ro8 8 13 97 5-35
Water-Ro10 10 15 97 5-35
Water-Ro15 15 20 97 5-35
Water-Ro20 20 26 97 5-35
Water-Ro25 25 35 97 5-35
Water-Ro30 30 40 97 5-35
Water-Ro50 50 67 97 5-35
Water-Ro100 100 135 97 5-35
Double stage reverse osmosis
Model Water output(m3/h) Minimum water intake(m3/h) Desalination rate(%) Temperature of the working water(℃)
Water-Ro0.3-2 0.3 1.6 98 5-35
Water-Ro0.5-2 0.5 2.2 98 5-35
Water-Ro1-2 1 2.8 98 5-35
Water-Ro2-2 2 4.1 97 5-35
Water-Ro3-2 3 6.5 97 5-35
Water-Ro4-2 4 7.8 97 5-35
Water-Ro6-2 6 12.5 97 5-35
Water-Ro8-2 8 15 97 5-35
Water-Ro10-2 10 15 97 5-35
Water-Ro15-2 15 31 97 5-35
Water-Ro20-2 20 38 97 5-35
Water-Ro25-2 25 41.25 97 5-35
Water-Ro30-2 30 47.5 97 5-35
Water-Ro50-2 50 79.5 97 5-35
Water-Ro100-2 100 155 97 5-35