• leak test sterilizer,leak test autoclave,autoclave ampoules,liquid autoclave,ampoule production

AM Series Steam Ampule(Oral Liquid)Leak Test Sterilizer

Steam leak test sterilizer adopts pure steam of high temperature and high pressure as the sterilizing medium, which can realize uniform sterilization in the temperature range of 105℃~130℃. It is widely used for sterilization, leak detection and cleaning of drugs such as ampoule, oral liquid and small volume intravenous infusion.

  • Product Description
  • Technical Parameters
  • Video

Steam Ampule(Oral Liquid)Leak Test Sterilizer Description:

This series of leak detection sterilizer is a high performance, high intelligence and small capacity filling drug sterilization, leak detection, cleaning equipment.
As a sterilization medium with pressure steam, a homogeneous sterilization can be achieved, and a multi-point replacement exhaust temperature is used to ensure that the sterilization indoor cold air is completely excluded, and the temperature rise is rapidly. Effectively eliminates the temperature dead angle due to the presence of cold air. After the end of the sterilization, the positive pressure leak detection was performed by vacuum, and the detection rate was 100%.

leak test sterilizer,sterilizing equipment,leak test autoclave,autoclave ampoules,liquid autoclave
The main machine of this series of equipment is horizontal rectangular structure, 3O4 or 316L stainless steel inner liner, all stainless steel wire drawing plate cover, with standard GMP verification interface. Industrial control system PLC+HMI has standard “user management, data storage, formula management” function, sterilization process can be traced, with independent data recording device and industrial control system to ensure data accuracy.

leak test sterilizer,leak test autoclave,autoclave ampoules,liquid autoclave,ampoule production
Process flow:

Pre-vacuum
Heating, sterilization
Leak test
Cleaning
Drying

leak test sterilizer,leak test autoclave,autoclave ampoules,liquid autoclave,ampoule production

 

Features:

1. Strictly design and manufacturing the boxes in accordance with the “steel pressure vessel”
2. National patent door lock device
3. Inner inflatable sealing technology of national patents
4. Reliable and stable microcomputer PLC + touch screen control. Advanced data record, printing, storage
5. Exquisite stainless steel decorative hood
6. Polyurethane and pearl rocky cotton double insulation layer
7. Device accompanying standard GMP verification interface
8. Optional remote monitoring system

leak test sterilizer,leak test autoclave,autoclave ampoules,liquid autoclave,ampoule production

 

Leave a Reply

Your email address will not be published. Required fields are marked *

Main Parameters & Utilities

Technical indicators
Design pressure 0.245Mpa
Vacuum -0.095Mpa
Working Pressure 0.22Mpa
Steam Source Pressure 0.4-0.6Mpa
Design Temperature 139℃
Water Source Pressure 0.1-0.3Mpa
Working Temperature 134℃
Compressed Air Pressure 0.5-0.7Mpa
Heat Equilibrium ≤±1℃

Size&Utilities

Specifications Model Overall Dimensions
L*M*H(mm)
Chamber Size
L*W*H(mm)
Steam Consumption
(kg/cycle)
Power
(KW)
Compressed Air
(m³/cycle)
Loading Cart(pcs) Cooling Water consumpation Net Weight
(kg)
AM-0.36 1195*1220*1720 1000*600*600 55 3 0.5 300 760
AM-0.6 1245*1300*1880 1050*680*850 75 3.5 0.8 400 1100
AM-0.8 1595*1300*1880 1400*680*850 75 3 1.1 600 1300
AM-1.2 1695*1370*1960 1500*750*1100 85 4 1.5 2 800 1900
AM-1.8 2445*1370*1960 2250*750*1100 100 4.5 2.0 3 1200 2450
AM-2.5 3195*1370*1960 3000*750*1100 180 6 3.0 4 1500 2800
AM-5.0 3635*1800*2200 3400*1000*1500 300 8 5.5 4 2500 4500

Note: The overall dimensions, chamber size, and the quantity of sterilizing car are for glass bottle. And there is a bit difference for soft bag.

Model 1ml 2ml 5ml 10ml 20ml
AM-0.36 32500 21000 8200 5500 33000
AM-0.6 64260 38880 17220 11160 6300
AM-1.2 127816 81664 33984 22400 11424
AM-1.8 191724 122496 50976 33600 17136
AM-2.5 255632 163328 67968 44800 22848
AM-5.0 605568 380160 158200 98208 50086