Mushroom Substrate Sterilizer Steam Sterilization For Mushroom Cultivation Description:
Substrate sterilizer is a special type of sterilizing pan (autoclave) specially designed to sterilize the growth medium used to produce the components of fungal mycelium (root structure) and fruiting body (fruiting body). The base material containers of the mushroom steam sterilizer are usually polypropylene bags or bowls and are not sealed, requiring a saturated steam process to reach typical sterilization temperatures of 250°F / 121°C or higher. For those who want to grow gourmet mushrooms, the Pre sterilized mushroom substrate creates the ideal environment for colonizing mycelium to produce fruit and grow. Designed for indoor growers.

Mushroom Substrate Sterilizer Features:
1. Saturated steam is used as sterilization medium in this series. It is specially used for high-temperature sterilization of non-sealed container loading medium.
2. The temperature of this series of mushroom sterilizer is adjustable and the temperature detection method is flexible. It has reliable processing effect on all kinds of standard and volume medium.
3. Mushroom autoclave machine adopts rectangular structure design. This autoclave has special pipeline design and advanced control system. Humanized design long life material: stainless steel, carbon steel, high intelligent automatic control system.

4. For proper sterilization, the pressure in the chamber must be maintained at 15 psi for a period of time. This means the temperature in the cabinet is about 121℃. At these temperatures, no living thing can survive. The duration of sterilization time depends largely on the composition and volume of the substrate. Specific sterilization times for specific substrates are mentioned in the technical section.
5. PLC automatic control system: automatic temperature control, automatic pressure control, automatic sterilizer time control
6. Adopt water ring vacuum pump, vacuum degree is less than -0.08mpa, at the same time in the sterilization process, control system, automatic exhaust steam adjustment according to the temperature of exhaust steam inner cavity.

7. Operation safety: electrical and mechanical double safety interlock protection system, operation safety
8. Autoclave safety device: overpressure protection, low water level protection, door interlock, overload, short circuit protection and other multiple safety structure, to ensure safe operation.
9. Equithermal distribution: the temperature in the reactor is evenly distributed, that is, the temperature difference is less than 1.0℃