• substrate sterilizer,sterilization of microbiological culture media,hospital sterilization,biological sterilization,lab sterilizer
  • substrate sterilizer,sterilization of microbiological culture media,hospital sterilization,biological sterilization,lab sterilizer

YG Lab Substrate Sterilizer Hospital Sterilization Of Microbiological Culture Media

Medium is a mixture of nutrients for the growth, reproduction and metabolism of microorganisms. Due to the different nutrient types of microorganisms and their different requirements for nutrients, as well as the different purposes of experiments and research, there are many types of culture media and different raw materials used. In order to achieve the purpose of experiment and research, the medium should be prepared according to the formula. Any medium should be thoroughly sterilized as soon as it is prepared for pure culture. The sterilization of general culture medium adopts high pressure steam sterilization.

  • Product Description
  • Technical Parameters
  • Video

Lab Substrate Sterilizer Hospital Sterilization Of Microbiological Culture Media Description:

In the process of fermentation, the main reasons for the sterilization of culture medium are as follows: if not sterilized, the substrate or product of biological reaction will be lost due to the consumption of miscellany bacteria, resulting in the decline of production capacity; Metabolites can also be produced by miscellaneous bacteria, which makes the extraction of products more difficult, resulting in lower yield and lower product quality.

substrate sterilizer,sterilization of microbiological culture media,hospital sterilization,biological sterilization,lab sterilizer

After a large number of hybrid bacteria, the PH value of the reaction solution will be changed, so that the reaction is abnormal; Some bacteria will decompose the product, so that the production failure; If the phagocyte contamination occurs, the producing bacteria cells will be lysed and the production will fail.
Substrate sterilizer is to kill the original bacteria in the medium itself or in the air attached to the bacteria, better allow the growth of the target bacteria (reduce the bacteria consumption of nutrients in the medium, and some bacteria will inhibit the growth of your target bacteria).

substrate sterilizer,sterilization of microbiological culture media,hospital sterilization,biological sterilization,lab sterilizer

In general, artificial culture is basically to make it grow as fast as possible or produce metabolites, so let it grow on the sterilization of microbiological culture media to reduce the culture time and improve economic benefits.

 

substrate sterilizer,sterilization of microbiological culture media,hospital sterilization,biological sterilization,lab sterilizer

Lab Substrate Sterilizer Features:

1. The sterilizer switch is easy and simple, the electronic lock can only be opened when the power is on, to avoid the accidental leakage of unsterilized substances due to power off or shutdown.
2. hospital sterilization can be clear display of the state, such as temperature, pressure, procedures and other relevant information in the process of operation.

substrate sterilizer,sterilization of microbiological culture media,hospital sterilization,biological sterilization,lab sterilizer
3. The biological sterilization pulse air purification is repeated until the pressure is higher than the corresponding temperature and the supersaturated steam pressure is generated to ensure the sterilization effect.
4. The lab sterilizer can adjust the steam emission according to the situation of the sterilized substance, and the hot air filtered by the vacuum pump and the filter membrane can quickly dry the sample, so that it can be used quickly.

substrate sterilizer,sterilization of microbiological culture media,hospital sterilization,biological sterilization,lab sterilizer
5. The mounting hole of the standard compound temperature probe of the high-pressure steam sterilizer is used to select the compound temperature probe to facilitate the verification of the internal sterilization effect.
6. The triple-pulse autoclave steam sterilizer and the pre-vacuum equipment are equipped with a powerful vacuum pump to forcibly empty the air retained in the cavity, so that the saturated steam can penetrate into the sterilized items well, so as to ensure the full and effective sterilization effect.

 

 

Leave a Reply

Your email address will not be published. Required fields are marked *

Design pressure Working Pressure Design Temperature Working Temperature Heat Equilibrium Vacuum Steam Source Pressure Water Source Pressure Compressed Air Pressure
0.245Mpa 0.22Mpa 139℃ 134℃ ≤±1℃ -0.095Mpa 0.4-0.6Mpa 0.2-0.3Mpa 0.6-0.8Mpa
Specifications Overall Dimensions Chamber Size Steam Consumption Power Water Consmption Net Weight
Model L*M*H(mm) L*W*H(mm) (kg/cycle) (KW) (kg/cycle) (kg)
Single/Double Door
YG-0.1 825*1080*1600 630*400*480 15 1 80 380
YG-0.25 895*1220*1720 760*600*600 20 1.5 150 650
YG-0.36 1195*1220*1720 1000*600*600 25 1.5 150 760
YG-0.6 1245*1300*1880 1050*680*850 30 2 200 1100
YG-0.8 1595*1300*1880 1400*680*850 35 3 250 1300
YG-1.2 1695*1370*1960 1500*750*1100 40 3 300 1900
YG-2.5 3195*1370*1960 3000*750*1100 75 4.5 450 2800
YG-5.0 3635*1800*2200 3400*1000*1500 150 7.5 600 4500

Video

YG 5.0 Steam Autoclave:

Medical Waste Disposal:

Circular Chamber Construction:

Rectangular Chamber Construction: