Incineration can not only treat solid waste, but also liquid waste and gas waste; Can be used for the treatment of municipal garbage and general industrial garbage, also can be used for the treatment of hazardous waste. The organic solid, liquid and gaseous wastes of hazardous wastes are usually treated by incineration. In the incineration of municipal solid waste (MSW), leachate and peculiar smell generated in the temporary storage process before incineration are often introduced into the incinerator for incineration.

  • Product Description
  • Technical Parameters
  • Video

Syringe Needle Sharps Incinerator Medical Waste Incinerator Description:

The safest method of disposing of biological and pharmaceutical wastes is incineration. Sharps Incinerator is ideally suited to treat all hospital waste, including sharp ware boxes, prior to needle treatment. It is important to note that medical waste incinerators will not destroy metal wastes during incineration, but will completely disinfect them, thereby reducing the risk of cross-contamination and preparing for the next phase of the waste management plan for safe recycling.

Needle Incinerator is specifically designed to provide optimal results when incinerating your medical waste. Sharps Medical Disposal machine is made of thickened steel and benefits from multi-layer refractories, saving substantial operating costs by 40% through improved thermal efficiency.

sharps incinerator,needle incinerator,sharps medical disposal,syringe needle disposal,medical waste incinerator

Syringe Needle Sharps Incinerator Features:

(1) Low operation and maintenance cost. The first burner is longer than the normal burner and is designed to save fuel.
(3) Environmental protection, double chamber design, smokeless, tasteless and pollution-free after waste incineration.
(4) The highest temperature can reach 1100-1300 degrees Celsius, can achieve the effect of sterilization and disinfection.
(5) long service life. Structural material – heavy section steel. Insulated and fireproof lined rooms.
(6) Easy to carry, small footprint

Syringe Needle Disposal  Details:

Burner

The burner has the functions of automatic ignition, fire protection, fault alarm and other functions such as high flame intensity, stable combustion, good safety and large power adjustment. The burner can manually adjust the air flow to change the flame size; the built-in pressure regulating valve ensures that the outlet pressure is stable; and the gas supply pressure can be adjusted to adjust the gas volume.

Electric Control Panel

It can lock the equipment in sequence and stop the process, power failure protection device, overload protection (electrical), alarm function. The electronic control system not only performs closed-loop control on the combustion temperature of the combustion chamber, but also performs closed-loop control on their oxygen supply, and coordinates the control between them, so that the control results of the system and the control of each process can meet the requirements, so that the whole system is at Closed-loop control.

sharps incinerator,needle incinerator,sharps medical disposal,syringe needle disposal,medical waste incinerator

Furnace Body

In the furnace, the flue gas flushes the material from the bottom to the outside, and the moisture in the material is dried to make the material ignite in time. Moreover, the front and rear arch refractories store heat and radiate the material, thereby ensuring the burning temperature of the material. The residence time of the flue gas is prolonged, so that the organic matter in the material and the fly ash is completely burned, and the destruction rate of the harmful substance is improved.

Good Exhaust System

So that the furnace always maintain negative pressure, will not produce backfire, safe and reliable operation.

Low Operating Cost

The whole set of device design is compact and reasonable, so that the waste fully, completely and thoroughly combustion, reduce fuel consumption, and the heat energy recovery rate is high, so that the operation cost is greatly reduced.

 

sharps incinerator,needle incinerator,sharps medical disposal,syringe needle disposal,medical waste incinerator

Leave a Reply

Your email address will not be published. Required fields are marked *

Model Dimensions(mm) Power(kw) Chimney(mm) Weight(kg) Capacity
WRMI-20 900*600*700 0.44 Φ140*6m 1500 10-20kg/batch
WRMI-30 1450*900*1020 0.63 Φ159*6m 2000 20-30kg/batch
WRMI-50 1800*1160*1200 0.81 Φ219*6m 3000 30-50kg/batch
WRMI-150 2000*1200*1360 1.01 Φ219*6m 4500 100-150kg/batch
WRMI-300 2200*1570*1510 1.8 Φ530*6m 8500 200-300kg/batch
WRMI-500 3000*1750*1710 3.34 Φ620*6m 12000 300-500kg/batch