• medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer
  • medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer
  • medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer
  • medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

YG Pre Vacuum Medical Waste Autoclave Steam Sterilizer Machine

Pulsating vacuum sterilizer is strictly designed and manufactured in accord with GMP technical Standard. It has passed ISO9001 quality management qualification standard and ISO13485:2003 Certificate of Quality Management System for Medical Devices. The relevant data and curve can be saved and printed automatically. This autoclave is suitable for pharmaceutical factory, hospital, scientific research institute and other units to sterilize and dry asepsis clothes, rubber goods, metal instruments, culture medium, etc.

 

  • Product Description
  • Technical Parameters
  • Video

Pre Vacuum Medical Waste Autoclave Steam Sterilizer Machine Description:

Application scope:
Medical waste Autoclave sterilizer is used to sterilize medical waste. Medical waste is infectious waste mainly produced by hospitals, health and epidemic prevention units, sanatoriums for patients, medical research units, etc., mainly including: Conventional medical waste, infectious waste, injury waste, pathological waste, pharmaceutical waste, chemical waste, etc.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

Quality system:
Autoclave steam Sterilizer has been designed and manufactured in accordance with ISO 9001-2000 and ISO 13485-2003 quality management system.
Environmental protection system:
Pre Vacuum Steam Sterilizer utilizes tap or chilled water supplies to reduce water use by up to 90%, making your facilities greener and more cost effective.
♦The distilled water and discharged gas are treated with environmental protection, no pollution and zero infection.
Safety system:
Vacuum steam sterilizer has multiple safety structures including overpressure protection, low water level protection, door interlocking system, overload and short circuit protection to ensure safe operation.
Vacuum system:
Vacuum system is used to deal with cold air and keep the temperature of the chamber uniform. All air leaving the chamber prior to sterilization is considered highly infectious and made sterile by a rigorous biological purification system.
Sterilization procedure:
– Automatic and manual operation mode;
– Automatic operation mode:
Microbial inactivation:
After sterilization, the number of microorganisms is reduced to less than 10-6.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

Medical Waste Autoclave Steam Sterilizer Features:

Sterilisation Chamber
1. Consisting of an inner chamber and an outer jacket, both made of SUS316L.
2. The “jacketed” autoclave chamber is also filled with steam, reducing condensation in the internal chamber and improving the saturation of steam and the uniform distribution of heat.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

Door Construction
1. Sealed with pressure steam.
2. The steriliser is equipped with a manual or electric door made of high quality stainless steel (optional).
3. The door can be horizontal or vertical, automatically sliding or swinging (radial arm) depending on the customer’s requirements.
4. the doors will have the unique arrangement of being able to be opened manually in the event of a power failure
5. with double door interlocking function to achieve effective separation of the operating area from the sterile area.
5. The seal is made of high temperature resistant and elastic silicone rubber, withstanding temperatures in excess of 350°C.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

Insulation Layer
1. The insulation material is made of aluminium silicate with a thickness of 150mm in accordance with GMP requirements.
2. The insulation cover is fully welded to prevent the insulation material from polluting the environment;
3. Ensure that the temperature of the area directly accessible to the operator does not exceed 50°C.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

Vacuum System
1. The system performs three pulsating vacuums in each sterilization cycle by default, so that the cold air remaining in the sterilization chamber is fully exhausted and the steam saturation is increased.
2. It consists of a high efficiency water ring vacuum pump, condenser, etc.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

Internal Control System
1. The control unit is based on advanced Siemens PLC or microprocessor technology.
2. It has perfect data recording, printing and saving functions, printing temperature, time and pressure curve graphs.
3. traceability of the production process and program control
4. Strict operation and management rights with three levels of password control to distinguish the operation rights of different users, namely operators, process personnel and management personnel.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

Humanised Program Selection
1. The design pressure and working pressure of the product are selected according to the characteristics of the sterilized articles.
2. A wide range of programs are available: dressing, instrument, BD, liquid, leak test, PCD, rapid, rubber, heavy duty, set 1 and set 2 programs.
3. Automatic control of the entire process, with low and high temperature alarms and protection against malfunction.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

Steam Generator
1. Steam supply is available as self-contained steam generator or external steam type.
2. Self-contained steam generator with automatic water filling, liquid level control and low water level automatic power off protection. 3.
3. External steam generators can be customised according to customer requirements.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

 

Sterilisation Trolley (optional)
1. Equipped with one or more trolleys for loading and unloading, the trolleys have removable baskets and wheels.
2. Sliding on rails, the trolley can be customised according to the customer’s requirements.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

Optional Remote Monitoring System

The sterilizer has wireless communication function, which can be connected to the remote monitoring end through terminal routing, and the data can be directly monitored in real time via WiFi or 4G/5G network to realize remote monitoring of sterilization status, temperature, sandwich pressure, F0 value, front and back door status and other information. With high precision and high acquisition rate, the sterilization environment can be monitored 24/7, improving the operational efficiency of sterilization.
If the temperature, pressure and time data are abnormal and do not meet the pressure steam sterilization requirements, the operator can see the abnormal information on the platform.

medical waste autoclave,autoclave steam sterilizer,autoclave sterilizers machine,pre vacuum steam sterilizer,vacuum steam sterilizer

Other Medical Waste Diposal:

Medical Autoclave With Shredder

Biomedical Waste Shredder

Medical Waste Baler

hazardous waste incinerator,bio waste incinerator,waste incineration,burning medical waste,medical waste incinerator

Medical Waste Incinerator

 

Leave a Reply

Your email address will not be published. Required fields are marked *

Design pressure Working Pressure Design Temperature Working Temperature Heat Equilibrium Vacuum Steam Source Pressure Water Source Pressure Compressed Air Pressure
0.245Mpa 0.22Mpa 139℃ 134℃ ≤±1℃ -0.095Mpa 0.4-0.6Mpa 0.2-0.3Mpa 0.6-0.8Mpa
Specifications Overall Dimensions Chamber Size Steam Consumption Power Water Consmption Net Weight
Model L*M*H(mm) L*W*H(mm) (kg/cycle) (KW) (kg/cycle) (kg)
Single/Double Door
YG-0.1 825*1080*1600 630*400*480 15 1 80 380
YG-0.25 895*1220*1720 760*600*600 20 1.5 150 650
YG-0.36 1195*1220*1720 1000*600*600 25 1.5 150 760
YG-0.6 1245*1300*1880 1050*680*850 30 2 200 1100
YG-0.8 1595*1300*1880 1400*680*850 35 3 250 1300
YG-1.2 1695*1370*1960 1500*750*1100 40 3 300 1900
YG-2.5 3195*1370*1960 3000*750*1100 75 4.5 450 2800
YG-5.0 3635*1800*2200 3400*1000*1500 150 7.5 600 4500

Video

Medical Waste Disposal:

YG 5.0 Steam Autoclave:

Circular Chamber Construction:

Rectangular Chamber Construction: